DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Ethernet Interface Operation
Revision 2
7–6
7.3.1.1
Configure HyperTerminal for Telnet Remote Control
Operation
Figure 7-3
.
Configure HyperTerminal
See
. Do these steps:
•
Make sure to define the Connect To Telnet connection properties
correctly (File
Properties) (Figure 7-3, left):
a.
Enter the unit’s Traffic/Management IP Address as the “Host
address” (e.g., 192.168.1.1).
b.
Enter TCP Port 23
c.
Set “Connect using” to TCP/IP (Winsock) instead of COM1 or
COM2.
as the “Port number”.
d.
Click
[
OK
]
to save your settings.
•
For ASCII Setup (File
Properties
Settings
ASCII Setup) (Figure
7-3, right):
a.
Check the “Send line ends with line feeds” option in the ‘ASCII
Sending’ section.
b.
Check the “Append line feeds to incoming line ends” option in
the ‘ASCII Receiving’ section.
c.
Click
[
OK
]
to save your settings.