DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Ethernet Interface Operation
Revision 2
7–7
7.4
HTTP (Web Server) Interface
A user-supplied web browser allows the full monitoring and control (M&C) of the
DT-4500 from its HTTP Interface. This non-secure embedded web application is
designed for, and works best with, Microsoft Internet Explorer Version 5.5 or
higher.
7.4.1
HTTP Interface User Login
1)
You must use DT-4500 Front Panel operation to select “Ethernet”
as your mode of operation prior to login. Failure to configure the
unit accordingly will cause the Login dialogue box to return you
to a blank web page.
2)
You must retrieve the assigned Management IP Address from the
DT-4500 Front Panel menu:
(SELECT:) CONFIG
Remote
Ethernet
Address
See
Chapter 6
.
FRONT PANEL OPERATION
for further details. You
may also need to consult with your network administrator to
determine the appropriate Management IP address assignment
for your converter.
Do these steps:
1.
From the PC, enter the default Management IP Address for the unit (e.g.,
http://192
.
168
.
1
.
4
) into the
Address
area of the browser.
2.
In the Login window, type the
User name
and
Password
,
and then click
OK
.