DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Serial Interface Operation
Revision 2
8–6
8.5.2
Baud Rate
The supported baud rates are 1200, 2400, 4800, 9600, 19200, and 38400 baud.
The default baud rate is 9600.
8.5.3
Asynchronous Character Format
The default asynchronous character format is 8-N-1: 8 data bits; no parity; 1 stop
bit.
8.5.4
Character Set
The command syntax uses the printable ASCII character set.
8.5.5
Response Timeout
A minimum of 500 milliseconds is provided before declaring a “no response”
instance, at which time the command is re-transmitted.
8.5.6
Bus Inactivity Requirement
Comtech EF Data recommends that you provide a minimum of 50 milliseconds
bus inactivity between the receipt of a response from an addressed converter
and issuing the next command on the serial bus.