DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Ethernet Interface Operation
Revision 2
7–20
7.5.3.3
Config | Pre-selects
Use this page to manage the converter operational pre-selects.
Figure 7-13. ‘Config | Pre-selects’ Page
Pre-Selects
You may create (program) up to 32 operating configurations, and load (recall)
them as needed.
Prior to the creation of any pre-selects, the Frequency and Attenuation
columns are populated with null values.
To program any pre-select (Numbers
01
through
32
), enter an operating RF
frequency in MHz, in 125 kHz steps (1 kHz steps optional), and an attenuation
level from
00
.
00
to
20
.
00
dB in
0
.
25
dB steps (0.1 dB steps optional). Click
[Change Configuration]
to save (program) the pre-select for future loading
(selection).
Load Pre-Select
Use the drop-down list to load (select) a previously defined pre-select from
memory. Click
[Change]
.