DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Front Panel Operation
Revision 2
6–19
Conv Temperature = OK ▲
High Speed Bus = OK ▼
Use the
keys to page between screens. Press
ENTER
or
CLEAR
to return to
the previous menu.
6.2.5.2
(FAULTS:) STORED
VIEW CLEAR-ALL
Use the
keys to select
View
or
Clear-All
. Press
ENTER
.
6.2.5.2.1
(FAULTS:) STORED
VIEW
If you select
View
and no faults exist in the stored faults log, the system displays
this message:
No Stored Faults.
Otherwise, stored faults log entries display as per this example:
Log05 01/23/11 09:27:15 ▲
Fault – HSB ▼
Use the
keys to page between screens. The faults log can store up to
100
faults. When a fault condition occurs, the unit assigns a number to the fault (in
the order received), date- and time-stamps the fault, and provides a condensed
description of the issue. When the fault condition clears, this action is recorded
in the same fashion as the fault was originally recorded, as shown per this
example:
Log09 01/23/11 10:45:35 ▲
Clear – HSB ▼