DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Serial Interface Operation
Revision 2
8–18
8.7.2.21
FRM (Firmware Information)
Use FRM to query the firmware loaded in the current production unit. This
includes firmware numbers, versions, and release dates. This query replaces the
legacy FRW query.
Description
Details
Return Firmware Information:
<DEV/FRM_{cr}
Confirmation:
>DEV/FRM_{cr}
Boot: {cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
Bulk1: {cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
Bulk2: {cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}{lf}]
where: FW-AAAAAAA = the firmware part number
B.B.BB = the version number
DD/MM/YY = Day/Month/Year firmware released
8.7.2.22
IMG (Firmware Image)
Use IMG to set or return selection of a valid bulk image as the next active boot
image.
Description
Details
Set Next FW Image:
<DEV/IMG_x{cr} where:
x = 1 or 2
Confirmation:
>DEV/IMG_x{cr}{lf}]
Return Active FW Image:
<DEV/IMG_{cr}
Confirmation: