9-14
Port #2 Inactivity Disconnect Timer
This timer determines how long Port #2 remains inactive before event macro 38 executes. Control Zone
2 Channel 6 must be enabled. This timer is programmable between 60 and 1799 seconds. The timer
default is 600 seconds.
Port #3 Inactivity Disconnect Timer
This timer determines how long Port #3 remains inactive before event macro 39 executes. Control Zone
3 Channel 6 must be enabled. This timer is programmable between 60 and 1799 seconds. The timer
default is 600 seconds.
Timed Message #1 Timer
This timer sets the timed message repeat period. This timer is programmable between 1.0 and 1799
seconds. The timer default is 300 seconds.
Timed Message #2 Timer
This timer sets the timed message repeat period. This timer is programmable between 1.0 and 1799
seconds. The timer default is 600 seconds.
Timed Message #3 Timer
This timer sets the timed message repeat period. This timer is programmable between 1.0 and 1799
seconds. The timer default is 900 seconds.
Timed Message #4 Timer
This timer sets the timed message repeat period. This timer is programmable between 1.0 and 1799
seconds. The timer default is 1200 seconds.
PTT Off Message #1 Timer
This timer sets the time between transmissions of the squelch tail message. The message occurs when
a repeater user stops transmitting. This timer is programmable between 1.0 and 1799 seconds. The
timer default is 1799 seconds.
PTT Off Message #2 Timer
This timer sets the time between transmissions of the drop out message. The message occurs when a
repeater stops transmitting. This timer is programmable between 1.0 and 1799 seconds. The timer
default is 1799 seconds.
DTMF Programming Length Timer
During the programming mode, this timer determines the maximum time the controller remains
unlocked. This timer is programmable between 60 and 1799 seconds. When initialize, this timer will
default to 600 second.
DTMF Access Sleep Timer
This timer determines the time required for the repeater to be at rest before the DTMF access code is
required to activate the repeater. This timer is programmable between 60 and 1799 seconds. The timer
default is 60 seconds.
Summary of Contents for CAT-800
Page 42: ...5 13 3634 SET PORT 3 CTCSS LOGIC COR OR CTCSS ACTIVE LO...
Page 87: ...11 1 Chapter 11 Drawings CAT 800 Repeater Controller Board...
Page 88: ...11 2 DR 800 Digital Audio Player...
Page 90: ...12 2 CAT 800 Sheet 1 of 4...
Page 91: ...12 3 CAT 800 Sheet 2 of 4...
Page 92: ...12 4 Sheet 3 of 4...
Page 93: ...12 5 Sheet 4 of 4...
Page 94: ...12 6 DR 800 Digital Audio WAV Player Sheet 1 of 1...