3-10
Zone 6 Control Channels
1. USER Output Switch #1 Enable
When this channel is enabled, switch #1 will perform per its pre-defined function. Connector J1-14 or
J2-6 will sink 150 MA to ground. At default this switch is defined as a DTMF remote controlled switch.
Use the User Macro #10 command [811] to turn the switch on and User Macro #11 command [810] to
turn the switch off. Use the programming command [*391X] to change the operation to a fan control or
CTCSS encoder switch.
2. USER Output Switch #2 Enable
When this channel is enabled, switch #2 will perform per its pre-defined function. Connector J1-15 or
J2-7 will sink 150 MA to ground. At default this switch is defined as a DTMF remote controlled switch.
Use the User Macro #12 command [821] to turn the switch on and User Macro #13 command [820] to
turn the switch off. Use the programming command [*392X] to change the operation to a fan control or
CTCSS encoder switch.
3. USER Output Switch #3 Enable
When this channel is enabled, switch #3 will perform per its pre-defined function. Connector J1-19 or
J3-6 will sink 150 MA to ground. At default this switch is defined as a DTMF remote controlled switch.
Use the User Macro #14 command [831] to turn the switch on and User Macro #15 command [830] to
turn the switch off. Use the programming command [*393X] to change the operation to a fan control or
CTCSS encoder switch.
4. USER Output Switch #4 Enable
When this channel is enabled, switch #4 will perform per its pre-defined function. Connector J1-20 or
J3-7 will sink 150 MA to ground. At default this switch is defined as a DTMF remote controlled switch.
Use the User Macro #16 command [841] to turn the switch on and User Macro #17 command [840] to
turn the switch off. Use the programming command [*394X] to change the operation to a fan control or
CTCSS encoder switch.
5. USER Output Switch #5 Enable
When this channel is enabled, switch #5 will perform per its pre-defined function. Connector J1-5 will
sink 150 MA to ground. At default this switch is defined as a DTMF remote controlled switch. Use the
User Macro #18 command [851] to turn the switch on and User Macro #19 command [850] to turn the
switch off. Use the programming command [*395X] to change the operation to a fan control or CTCSS
encoder switch.
6. Reserved Enable
7. Reversed Enable
8. Reversed Enable
Summary of Contents for CAT-800
Page 42: ...5 13 3634 SET PORT 3 CTCSS LOGIC COR OR CTCSS ACTIVE LO...
Page 87: ...11 1 Chapter 11 Drawings CAT 800 Repeater Controller Board...
Page 88: ...11 2 DR 800 Digital Audio Player...
Page 90: ...12 2 CAT 800 Sheet 1 of 4...
Page 91: ...12 3 CAT 800 Sheet 2 of 4...
Page 92: ...12 4 Sheet 3 of 4...
Page 93: ...12 5 Sheet 4 of 4...
Page 94: ...12 6 DR 800 Digital Audio WAV Player Sheet 1 of 1...