5-18
Pre-Voice Delay Timer [*622*]
This timer determines the time after PTT goes active and the voice synthesizer begins to speak. This
timer is programmable between 0.1 and 9.9 seconds. The timer default is 0.5 seconds.
Turn on Delay Timer [*623*]
When the repeater is at rest, this timer sets the time COR must be present before the repeater will
activate. This timer is programmable between 0.1 and 9.9 seconds. Example: To program this timer to
1.5 seconds, key-up and enter [*623*15]. Un-key and the voice will say: "CONTROL OK." When
initialize this timer will default to 1.0 seconds. This timer also sets the turn on delay time for the Port
#2 input.
DTMF Muting Timer [*624*]
This timer determines the time the transmit audio will continue to be muted after the entry of the last
DTMF tone. When initialize, this timer defaults to 1 second.
Read Timer Settings [*601-*624]
Key-up and send [*601]. Un-key and the voice synthesizer will read back the setting of the Port #1
time-out timer. The voice will say: "TIMER 601 IS THREE MINUTES.
Courtesy Tone
Memory space is provided for [8] custom courtesy tones. Each tone can consist of up to three different
tone frequencies of various lengths and separations.
Send Courtesy Tone (1-8)
Key-up and send [*91X]. Un-key and the CAT-800 will transmit the courtesy tone. "X" represents the
courtesy tone table location.
Program Courtesy Tone (1-8)
Key-up and send [*92X] followed by the table position, frequency, duration and separation numbers
from the courtesy tone-programming table. Example: Program courtesy tone table location 5 with a
tone of 622Hz and duration of 150msec.
COURTESY TONE DEFAULT TABLE
Tone Freq Time
Space Freq Time
Space Freq Time
1 330
Hz
150mSEC 50mSEC 493
Hz
150mSEC 50mSEC 660
Hz
150mSEC
2 660
Hz
150mSEC 50mSEC 493
Hz
150mSEC 50mSEC 330
Hz
150mSEC
3 880
Hz
150mSEC 50mSEC 1046
Hz
150mSEC
4 880
Hz
150mSEC
5 660
Hz
150mSEC
6 440
Hz
150mSEC
7 440
Hz
150mSEC 0mSEC 660
Hz
150mSEC
8 660
Hz
150mSEC 0mSEC 440
Hz
150mSEC
Tone Frequency (622Hz)
Table Position Tone Duration (150msec).
Programming Command
*92 5 20 3
Summary of Contents for CAT-800
Page 42: ...5 13 3634 SET PORT 3 CTCSS LOGIC COR OR CTCSS ACTIVE LO...
Page 87: ...11 1 Chapter 11 Drawings CAT 800 Repeater Controller Board...
Page 88: ...11 2 DR 800 Digital Audio Player...
Page 90: ...12 2 CAT 800 Sheet 1 of 4...
Page 91: ...12 3 CAT 800 Sheet 2 of 4...
Page 92: ...12 4 Sheet 3 of 4...
Page 93: ...12 5 Sheet 4 of 4...
Page 94: ...12 6 DR 800 Digital Audio WAV Player Sheet 1 of 1...