J-10
Compaq ServerNet II PCI Adapter and Switch Installation Guide
snetSwitchSANManFailover
ServerNet II Switch SANMan failure has been detected.
Specific Trap:
108
Severity:
Minor
Summary:
SANMan failover detected. Primary SANMan is snetSwitchPrimarySANManSnetID
(snetSwitchPrimarySANManName), Backup SANMan is
snetSwitchBackupSANManSNetID (snetSwitchBackupSANManName). Failure type is
snetSwitchFailoverEventType.
Enable:
Disable:
Always enabled
Cannot be disabled
Returned Variable
Indicates
snetSwitchPrimarySANManSNetID
Contains the SNID of the current primary SANMan if
snetSwitchFailoverEventType = 2 or 4
Contains the SNID of the new primary SANMan if
snetSwitchFailoverEventType = 3
Contains the SNID of the new backup SANMan if
snetSwitchFailoverEventType = 5
snetSwitchPrimarySANManName
Name of the current primary SANMan in the ServerNet II SAN.
snetSwitchBackupSANManSNetID
Contains the SNID of the current backup SANMan if
snetSwitchFailoverEventType = 2 or 4
Contains the SNID of the fail primary SANMan if
snetSwitchFailoverEventType = 3 or 5
snetSwitchBackupSANManName
Name of the current backup SANMan in the ServerNet II SAN.
snetSwitchFailoverEventType
The type of failure detected:
2 = Backup not reachable
3 = Backup took over
4 = Primary not reachable
5 = Primary took over
Possible Cause or Condition
Possible Solution
Primary backup SANMan has failed
Powered off
Apply power
Hung, doing nothing
Reboot
Maintenance
Not a problem, just restart when finished