POST Error Codes
Writer: Your Name Saved by: Lydia Sanchez Saved date: 08/26/99 8:59 AM
Pages: 13 Words: 2459 Template: c:\word7\templates\commapp.dot
File Name e-appe.doc Part Number 158415-001
Power-On Self-Test Messages
Continued
Message
Beeps*
Probable Cause
Recommended Action
914-Hood Lock Coil
is not Connected
None
Smart Cover Lock mechanism
is missing or not connected.
1. Reconnect or replace Smart Cover
Lock.
2. Reseat or replace Smart Cover
Lock cable.
916-Thermal Sensor
from Processor
Heatsink is not
Connected
None
Processor heatsink cable not
connected to system board.
Reseat or replace the processor
heatsink cable going to the system
board.
917-Expansion Riser
not Detected
None
Riser board not seated or not
installed.
Install riser board if missing or remove
and reseat to ensure good connection.
1151-Serial Port 1
Address Conflict
Detected
2S
Both external and internal
serial ports are assigned to
COM1.
1. Remove any serial port expansion
cards.
2. Clear
CMOS.
3. Reconfigure card resources and/or
run Computer Setup (F10 Setup).
1152- Serial Port 2
Address Conflict
Detected
2S
Both external and internal
serial ports are assigned to
COM2.
1. Remove any serial port expansion
cards.
2. Clear
CMOS.
3. Reconfigure card resources and/or
run Computer Setup (F10 Setup).
1155-Serial Port
Address Conflict
Detected
2S
Both external and internal
serial ports are assigned to
same IRQ.
1. Remove any serial port expansion
cards.
2. Clear
CMOS.
3. Reconfigure card resources and/or
run Computer Setup (F10 Setup).
1201-System Audio
Address Conflict
Detected
2S
Device IRQ address conflicts
with another device.
Reset the IRQ.
* L = Long, S = Short