610 - 03
Previously exceeded max
3.
Replace the diskette drive
soft error limit
power and signal cables.
4.
Replace the diskette drive
610 - 04
Previously exceeded max
assembly.
hard error limit
5.
Replace the system board.
610 - 05
Failed to reset controller
* 286 based COMPAQ Personal
Computers only
610 - 06
Fatal error while reading
610 - 07
Fatal error while writing
610 - 08
Failed compare of write/
read/compare
------------------------------------------------------------------------------
Error
Error
Required
Code
Description
Action
------------------------------------------------------------------------------
Diskette Drive
6yy - xx
------------------------------------------------------------------------------
6xx - 09
Failed to format a track
The following steps apply to all
6yy - xx related error codes.
610 - 10
Failed sector wrap test
1.
Check shunt jumper J2 setting
610 - 20
Failed to get drive type
on the diskette/tape
controller board (see
610 - 21 **
Failed to get change line
Chapter 8). *
status
2.
Replace the diskette/tape
controller board. *
610 - 22
Failed to clear change
3.
Replace the diskette drive
power and signal cables.
610 - 23
Failed to set drive type in
4.
Replace the diskette drive
ID media
assembly.
5.
Replace the system board.
610 - 24
Failed to read media
* 286 based COMPAQ Personal
610 - 25
Failed to verify media
Computers only
610 - 26
Failed to read media in
** The following applies to
speed test
286 based computers:
610 - 27
Failed speed limits
For a 1.2 megabyte diskette
drive, replace the diskette
610 - 28
Failed write protect test
drive.
For a 360 Kbyte
diskette drive, a drive
610 - 29
Failed to read media in
modification has not been
file write test
performed.
See Service
Bulletin 25.
610 - 40
Cylinder 0 Error
------------------------------------------------------------------------------
Error
Error
Required
Code
Description
Action
------------------------------------------------------------------------------
Serial
11yy - xx
------------------------------------------------------------------------------
1101 - 01
Serial Port Test, UART
The following steps apply to all
DLAB bit failure
11yy - xx related error codes: