Cooling
Forced air provided by 16 VDC fan
Current
2 amps, maximum at input voltage of 120 VAC,
60 Hz
------------------------------------------------------------------------------
VDC Output:
Nominal
Current
Current
Regulation
Voltage
Amps
Amps
Tolerance
VDC
Minimum
Maximum *
Percent
------------------------------------------------------------------------------
+ 5.0
1.5
15.0
2
- 5.0
0.0
0.5
5
+ 12.25
1.0
5.0
2
+ 12.25
0.0
1.5
3
(internal monitor)
- 12.0
0.0
1.0
5
------------------------------------------------------------------------------
* These values are maximum values based on nominal operating conditions for
temperature, line voltage, line frequency, and altitude.
==============================================================================