2 Short
Controller Board
------------------------------------------------------------------------------
6XX
None
Disk Drive Assembly
------------------------------------------------------------------------------
170X
None
Fixed Disk Drive Assembly
==============================================================================
Chapter 5.3 Diagnostic Error Codes
DIAGNOSTIC error codes occur if the system recognizes a problem while running
the COMPAQ DIAGNOSTICS Program.
These error codes help identify possible
defective subassemblies.
Table 5.3 lists all possible error codes, a description of the error
condition, and the action required to resolve the error condition.
In each case, the required action lists prioritized steps necessary to
correct the problem.
After each step is completed, run DIAGNOSTICS to verify
whether the error condition has been corrected.
If the error code reappears,
perform the next step, then run the DIAGNOSTICS Program.
Follow this
procedure until the DIAGNOSTICS Program no longer detects an error condition.
For assistance in the removal and replacement of a particular subassembly, see
Chapter 7, "Removal and Replacement Procedures."
Table 5-3.
DIAGNOSTIC Error Codes
==============================================================================
Error
Error
Required
Code
Description
Action
------------------------------------------------------------------------------
Processor
1yy - xx
------------------------------------------------------------------------------
101 - 01
286 CPU test failed
Replace the system board.
------------------------------------------------------------------------------
102 - 01
287 Coprocessor initial
The following steps apply to error
status word incorrect
codes 102 - 01 through 102 - 15:
102 - 02
287 Coprocessor initial
1.
Replace the 287 Coprocessor.
control word incorrect
2.
Replace the system board.
102 - 03
287 Coprocessor tag word
not all ones
102 - 04
287 Coprocessor tag word
not all zeros
102 - 05
287 Coprocessor exchange
command failed
102 - 06
287 Coprocessor masked
exception incorrectly
handled
102 - 07
287 Coprocessor unmasked
exception codes incorrectly
handled