3-22
Compaq AlphaServer ES40 Service Guide
3.4
Power-Up Error Messages
Error messages at power-up may be displayed by the RMC, SROM, and
SRM. A few SROM messages are announced by beep codes.
3.4.1
SROM Messages with Beep Codes
Table 3–1 Error Beep Codes
Beep
Code
Associated
Messages
Meaning
1
Jump to
Console
SROM code has completed execution. System jumps to
SRM console. SRM messages should start to be
displayed. If no SRM messages are displayed, it may
indicate corrupted firmware. See Section 3.4.2.
1-3
VGA monitor not plugged in. The first beep is a long
beep.
1-1-4
ROM err
The ROM err message is displayed briefly, then a single
beep is emitted, and Jump to Console is displayed. The
SROM code is unable to load the console code; a flash
ROM header area or checksum error has been detected.
See Section 3.4.2.
2-1-2
Cfg ERR n
Cfg ERR s
Configuration error on CPU n (n is 0, 1, 2, or 3) or a
system configuration error. The system will still power
up.
1-2-4
BC error
CPU error
BC bad
Backup cache (B-cache) error. Indicates a bad CPU.
1-3-3
No mem
No usable memory detected. Some memory DIMMs
may not be properly seated or some DIMM sets may be
faulty. See Section 3.4.3.
Summary of Contents for AlphaServer ES40
Page 4: ......
Page 16: ......
Page 20: ......
Page 68: ......
Page 104: ......
Page 162: ......
Page 170: ...5 8 Compaq AlphaServer ES40 Service Guide Figure 5 4 FRU List Designator ...
Page 172: ...5 10 Compaq AlphaServer ES40 Service Guide Figure 5 5 Evidence Designator ...
Page 184: ...5 22 Compaq AlphaServer ES40 Service Guide Figure 5 7 Display Error Frames Screen ...
Page 193: ...Error Logs 5 31 Figure 5 14 Deleting an Old Error Frame ...
Page 194: ......
Page 280: ......
Page 310: ...8 30 Compaq AlphaServer ES40 Service Guide Figure 8 14 Aligning DIMM in MMB PK0953a ...
Page 332: ......
Page 336: ......
Page 358: ......
Page 444: ......