5-18
Compaq AlphaServer ES40 Service Guide
5.4
Environmental Errors Captured by SRM
If an environmental error occurs while the SRM console is running, a
logout frame similar to Example 5–1 is sent to the console output
device. The logout frame is preceded by the message “***unexpected
system event through vector 680 on CPU n.” (usually CPU 0.) For
register definitions see Appendix D.
Example 5–1 Console Level Environmental Error Logout Frame
P00>>>
*** unexpected system event through vector 680 on CPU 0
os_flags 0000000000000000
cchip_dirx 0004000000000000
tig_smir 0000000000000008
tig_cpuir 000000000000000f
tig_psir 0000000000000003
lm78_isr 0000000000000000
door_open 0000000000000004
➊
temp_warning 0000000000000000
fan_ctrl_fault 0000000000000000
power_down_code 0000000000000000
reserved_1 0000000000000000
➊
This example shows a fan door open event.
Summary of Contents for AlphaServer ES40
Page 4: ......
Page 16: ......
Page 20: ......
Page 68: ......
Page 104: ......
Page 162: ......
Page 170: ...5 8 Compaq AlphaServer ES40 Service Guide Figure 5 4 FRU List Designator ...
Page 172: ...5 10 Compaq AlphaServer ES40 Service Guide Figure 5 5 Evidence Designator ...
Page 184: ...5 22 Compaq AlphaServer ES40 Service Guide Figure 5 7 Display Error Frames Screen ...
Page 193: ...Error Logs 5 31 Figure 5 14 Deleting an Old Error Frame ...
Page 194: ......
Page 280: ......
Page 310: ...8 30 Compaq AlphaServer ES40 Service Guide Figure 8 14 Aligning DIMM in MMB PK0953a ...
Page 332: ......
Page 336: ......
Page 358: ......
Page 444: ......