4-8
Compaq AlphaServer ES40 Service Guide
4.3
cat el and more el
The cat el and more el commands display the contents of the console
event log.
In Example 4–2, the console reports that CPU 1 did not power up and fans 1
and 2 failed.
Example 4–2 more el
>>> more el
*** Error - CPU 1 failed powerup diagnostics ***
➊
Secondary start error
EV6 BIST = 1
STR status = 1
CSC status = 1
PChip0 status = 1
PChip1 status = 1
DIMx status = 0
TIG Bus status = 1
DPR status = 0
CPU speed status = 0
CPU speed = 0
Powerup time = 00-00-00 00:00:00
CPU SROM sync = 0
*** Error - Fan 1 failed ***
➋
*** Error - Fan 2 failed ***