4-48
Compaq AlphaServer ES40 Service Guide
Table 4–2 Show Error Message Translation
Bit Mask
(E Field)
Text Message
Meaning and Action
01
<fruname> Hardware Failure
Module failure. FRUs that are known to
be connected but are unreadable are
considered hardware failures. An
example is power supplies.
02
<fruname> TDD - Type:0 Test: 0
SubTest: Error: 0
Serious error. Run the Compaq Analyze
GUI, if necessary, to determine what
action to take. If you cannot run Compaq
Analyze, replace the module.
04
<fruname> SDD - Type:0
LastLog: 0 Overwrite: 0
Serious error. Compaq Analyze (CA) has
written a FRU callout into the SDD area
and DPR global area. Follow the
instructions given by Compaq Analyze.
08
<fruname> EEPROM
Unreadable
Reserved.
10
<fruname> Bad checksum 0 to
64 EXP:01 RCV:02
Informational. Use the clear_error
command to clear the error unless TDD
or SDD is also set.
20
<fruname> Bad checksum 64 to
126 EXP:01 RCV:02
Informational. Use the clear_error
command to clear the error unless TDD
or SDD is also set.
40
<fruname> Bad checksum 128 to
254 EXP:01 RCV:02
Informational. Use the clear_error
command to clear the error unless TDD
or SDD is also set.
40
<fruname> SYS_SERIAL_NUM
Mismatch
Informational. Use the clear_error
command to clear the error unless TDD
or SDD is also set.
Summary of Contents for AlphaServer ES40
Page 4: ......
Page 16: ......
Page 20: ......
Page 68: ......
Page 104: ......
Page 162: ......
Page 170: ...5 8 Compaq AlphaServer ES40 Service Guide Figure 5 4 FRU List Designator ...
Page 172: ...5 10 Compaq AlphaServer ES40 Service Guide Figure 5 5 Evidence Designator ...
Page 184: ...5 22 Compaq AlphaServer ES40 Service Guide Figure 5 7 Display Error Frames Screen ...
Page 193: ...Error Logs 5 31 Figure 5 14 Deleting an Old Error Frame ...
Page 194: ......
Page 280: ......
Page 310: ...8 30 Compaq AlphaServer ES40 Service Guide Figure 8 14 Aligning DIMM in MMB PK0953a ...
Page 332: ......
Page 336: ......
Page 358: ......
Page 444: ......