SRM Console Diagnostics
4-19
-bs <block_size>
Specifies the block size (hex) in bytes. The default is 200
(hex).
-bc <block_per_io>
Specifies the number of blocks (hex) per I/O. On devices
without length (tape), use the specified packet size or
default to 2048. The maximum block size allowed with
variable length block reads is 2048 bytes. The default
is 1.
-d1 <buf1_string>
String argument for eval to generate buffer1 data
pattern from. Buffer1 is initialized only once before any
I/O occurs. Default = all bytes set to hex 5A’s.
-d2 <buf2_string>
String argument for eval to generate buffer2 data
pattern from. Buffer2 is initialized only once before any
I/O occurs. Default = all bytes set to hex 5A’s.
-a <action_string>
Specifies an exerciser action string, which determines
the sequence of reads, writes, and compares to various
buffers. The default action string is ?r. The action string
characters are:
•
r
Read into buffer1.
•
W Write from buffer1.
•
R Read into buffer2.
•
W Write from buffer2.
•
N
Write without lock from buffer1.
•
N Write without lock from buffer2.
•
c
Compare buffer1 with buffer2.
•
-
Seek to file offset prior to last read or write.
Continued on next page
Summary of Contents for AlphaServer ES40
Page 4: ......
Page 16: ......
Page 20: ......
Page 68: ......
Page 104: ......
Page 162: ......
Page 170: ...5 8 Compaq AlphaServer ES40 Service Guide Figure 5 4 FRU List Designator ...
Page 172: ...5 10 Compaq AlphaServer ES40 Service Guide Figure 5 5 Evidence Designator ...
Page 184: ...5 22 Compaq AlphaServer ES40 Service Guide Figure 5 7 Display Error Frames Screen ...
Page 193: ...Error Logs 5 31 Figure 5 14 Deleting an Old Error Frame ...
Page 194: ......
Page 280: ......
Page 310: ...8 30 Compaq AlphaServer ES40 Service Guide Figure 8 14 Aligning DIMM in MMB PK0953a ...
Page 332: ......
Page 336: ......
Page 358: ......
Page 444: ......