2-4
Compaq AlphaServer ES40 Service Guide
Table 2–1 Power Problems
Symptom
Action
Reference
System does not
power on.
•
Check error messages on the OCP.
•
Check that AC power is plugged in.
•
Check that the ambient room
temperature is within
environmental specifications
(10–40° C, 50–104° F).
•
Check the Power setting on the
control panel. Toggle the Power
button to off, then back on to clear a
remote power disable.
•
Check that internal power supply
cables are plugged in at the system
motherboard.
Power supply shuts
down after a few
seconds
The system may be powered off by one
of the following:
Loss of AC power
RMC power off command
System software
Multiple fan failure
Overtemperature condition
Power supply failure (If N+1 config.
multiple power supply failure
Faulty CPU (CPU DC/DC converter
failure)
If AC power is present, use the RMC
env command to check environmental
status.
Check jumper J26. If the system must
be kept running, this jumper can be
positioned to override an overtempera-
ture condition.
Chapter 7
Appendix B
Summary of Contents for AlphaServer ES40
Page 4: ......
Page 16: ......
Page 20: ......
Page 68: ......
Page 104: ......
Page 162: ......
Page 170: ...5 8 Compaq AlphaServer ES40 Service Guide Figure 5 4 FRU List Designator ...
Page 172: ...5 10 Compaq AlphaServer ES40 Service Guide Figure 5 5 Evidence Designator ...
Page 184: ...5 22 Compaq AlphaServer ES40 Service Guide Figure 5 7 Display Error Frames Screen ...
Page 193: ...Error Logs 5 31 Figure 5 14 Deleting an Old Error Frame ...
Page 194: ......
Page 280: ......
Page 310: ...8 30 Compaq AlphaServer ES40 Service Guide Figure 8 14 Aligning DIMM in MMB PK0953a ...
Page 332: ......
Page 336: ......
Page 358: ......
Page 444: ......