![background image](http://html1.mh-extra.com/html/compaq/alphaserver-ds20/alphaserver-ds20_service-manual_2646415066.webp)
2-16
AlphaServer DS20 Service Manual
2.8.2
Description of the Error
After “double clicking” the Problem Found: hot spot on the Compaq Analyze
screen a full description of the error is displayed and a FRU and its location is
called out. Example 2–6 shows a Compaq Analyze error report.
Example 2–6 Compaq Analyze Error Report
Problem Found: An uncorrectable system fan 0 error detected.
Managed Entity:
System Entity: enugu Error Environment:
Record Number :
Event ID_Count:2Event ID_Prefix:15008
Event Time:
Time of Error : Thu, 11 Mar 1999 12:43:58 –0500
Brief Description:
An uncorrectable system fan 0 error detected.
Callout ID:
0020050000072E05
Severity:
2
Reporting Node:
enugu
Full Description:
An uncorrectable system fan 0 error has been diagnosed. This System
error requires replacement service to be administered to Fan 0 Field
Replaceable Unit (FRU). This FRU is physically located in the
compartment to the right of the system card cage and is System Fan 0
– Upper Fan.
FRU List:
Probability: High
Manufacturer: Compaq
Device Type: Power, Cooling, and Temperature
Physical Location: Slot System Fan 0 --
FRU Part Number: System fan 0 pn from config tree
FRU Serial Number: Fru SN from config tree
FRU Firmware Rev: NA