Removal and Replacement
4-15
Removal
1.
Shut down the operating system and turn the system off.
2.
Expose the card cage side of the system (see Section 4.3).
3.
To remove the faulty option: Disconnect cables connected to the option. Remove
cables to other options that obstruct the option you are removing. Unscrew the
small Phillips head screw securing the option to the card cage. Slide it from the
system.
Replacement
Reverse the steps in the Removal procedure.
Verification — DIGITAL UNIX and OpenVMS Systems
1.
Power up the system (press the Halt button if necessary to bring up the SRM
console) and run the ECU to restore ISA configuration data.
2.
Issue the show config command or show device command at the console prompt
to verify that the system sees the option you replaced.
3.
Run any diagnostic appropriate for the option you replaced.
Verification — Windows NT Systems
1.
Start AlphaBIOS Setup, select Display System Configuration, and press Enter.
2.
Using the arrow keys, select PCI Configuration or ISA Configuration to
determine that the new option is listed.