Managing the System Remotely
B-7
help or ?
The help or ? command displays the RCM firmware commands.
poweroff
The poweroff command requests the RCM to power off the system. The poweroff
command is equivalent to pressing the On/Off button on the control panel to the off
position.
RCM>poweroff
If the system is already powered off or if switch 3 (RPD DIS) on the switchpack has
been set to the on setting (disabled), this command has no immediate effect.
To power the system on again after using the poweroff command, you must issue the
poweron command.
If, for some reason, it is not possible to issue the poweron command, the local
operator can start the system as follows:
1.
Press the On/Off button to the off position and disconnect the power cord.
2.
Reconnect the power cord and press the On/Off button to the on position.
poweron
The poweron command requests the RCM to power on the system. The poweron
command is equivalent to pressing the On/Off button on the control panel to the on
position. For the system power to come on, the following conditions must be met:
•
AC power must be present at the power supply inputs.
•
The On/Off button must be in the on position.
•
All system interlocks must be set correctly.
The RCM exits command mode and reconnects the user’s terminal to the system
console port.
RCM>poweron
Focus returned to COM port
NOTE: If the system is powered off with the On/Off button, the system will not
power up. The RCM will not override the “off” state of the On/Off button. If the
system is already powered on, the poweron command has no effect.