- permanent - the optical and/or acoustic signalling is deactivated
until new alarm occurs. In this case, the "Reactivate muted alarm
signalling" item must be switched off in the device configuration.
- time-limited (temporary) - if the alarm after the set time interval
is still current, the optical and/or acoustic signalling is activated
again. The time interval can be set in the device configuration
under the item "Reactivate muted alarm signalling".
By local keypad on the device only deactivate the optical and/or
acoustic signalling; Sign ALARM at the top of the display is displayed
for the whole time of the alarm condition.
Alarm events - Memory occupancy
___________________
Use this panel setting, if an overrun of the pre-set limit value of the data
memory occupancy needs to be signalled. The signalling mode may
be selected optionally as optical (by means of a LED diode), acoustical,
or it may be realized by sending a warning SMS message up to as 4
selected recipients.
Alarm events - System failure
_______________________
These panel choices make it possible to set the so-called system
alarms, which indicate some technical failure of the datalogger or of
some of the probes connected to it. The signalling mode may be
selected optionally as optical (every time by means of a red LED
diode), acoustical, or it may be realized by sending a warning SMS
message up to 4 selected recipients.
The device can respond to the following conditions:
a)
Measurement error on any channel
...... e. g. a probe has been
disconnected or broken.
b)
Device configuration error
…... the device configuration has
been disturbed unexpectedly.
c)
External power failure
...... the USB connector of the device
can be used to charge the battery, or it can be permanently
connected to external power (USB charger or computer). This
state can therefore be used as an external power failure
indicator.
d)
Low battery
…. it informs that it is necessary to connect
external power and charge the internal battery, see
e)
Time setting error or battery is
discharged
…. the battery has
run out of charge.
Modem - General
_________________________________
In the configuration enter the PIN code for your SIM card, if required
(given by the settings of the SIM card used). By default, your device is
Summary of Contents for U0110G
Page 5: ...IE LGR UxxxxM 23 5 Dataloggers UxxxxM and UxxxxG U0141M U0141G models...
Page 61: ...IE LGR UxxxxM 23 61 Dimensions U0110M U0110G U8410M U8410G U0121M U0121G...
Page 62: ...62 IE LGR UxxxxM 23 U0141M U0141G U3120M U3120G U4440M U4440G...
Page 63: ...IE LGR UxxxxM 23 63 U3121M U3121G U3631M U3631G...
Page 64: ...64 IE LGR UxxxxM 23 U0141TM U0141TG U0843M U0843G U5841M U5841G U6841M U6841G U7841M U7841G...