IE-LGR-UxxxxM-23
23
U5841M, U5841G
Datalogger with 3 inputs 0
– 10 V
and 1 binary input
This model is used to measure up to three voltage
inputs 0-10 V DC while allowing one binary input to be
monitored. The voltage inputs are not galvanically
isolated from one another. This means that the negative
terminals ("-") are connected to each other. These facts
must be taken into consideration when designing the
device into the circuit. Incorrect connection may cause
degradation of the measured values.
Binary input serves to monitor voltage signals or
signals coming from a dry contact. The binary input
changes are registered immediately, irrespectively
of the recording interval setting. To safe record the input
status, the signal must be present for at least 1 s. Unlike
the U0843M (U0843G) model, this input can capture
connected/ disconnected voltage status.
Input signals are connected to a pluggable terminal
block. The device has not a protection against the
ingress of water or dust. Do not use device at places
where such conditions can be expected. The maximum
length of the input wires should not exceed 30 m. It is
recommended to use shielded cables.
Connection:
The procedure for connecting the wires to the terminals
can be found in
Summary of Contents for U0110G
Page 5: ...IE LGR UxxxxM 23 5 Dataloggers UxxxxM and UxxxxG U0141M U0141G models...
Page 61: ...IE LGR UxxxxM 23 61 Dimensions U0110M U0110G U8410M U8410G U0121M U0121G...
Page 62: ...62 IE LGR UxxxxM 23 U0141M U0141G U3120M U3120G U4440M U4440G...
Page 63: ...IE LGR UxxxxM 23 63 U3121M U3121G U3631M U3631G...
Page 64: ...64 IE LGR UxxxxM 23 U0141TM U0141TG U0843M U0843G U5841M U5841G U6841M U6841G U7841M U7841G...