24
IE-LGR-UxxxxM-23
U6841M, U6841G
Datalogger with 3 inputs 0 - 20 mA
and 1 binary input
This model is used to measure up to three signals from
current loops (0 to 20) mA DC while allowing one binary
input to be monitored. The current inputs are passive
and are not galvanically isolated from one another.
This means that the connected sensors cannot be
connected to the current loop and the negative terminals
("-") are connected to each other. These facts must be
taken into consideration when designing the device into
the circuit. Incorrect connection may cause degradation
of the measured values. Standard outputs (4 to 20) mA
can also be measured with current inputs without any
problems.
Binary input serves to monitor voltage signals or signals
coming from a dry contact. The binary input changes are
registered immediately, irrespectively of the recording
interval setting. To safe record the input status, the signal
must be present for at least 1 s. Unlike the U0843M
(U0843G) model, this input can capture connected/
disconnected voltage status.
Input signals are connected to a pluggable terminal block.
The device has not a protection against the ingress of
water or dust. Do not use device at places where such
conditions can be expected. The maximum length of the
input wires should not exceed 30 m. It is recommended
to use shielded cables.
Connection:
The procedure for connecting the wires to the terminals
can be found in
Summary of Contents for U0110G
Page 5: ...IE LGR UxxxxM 23 5 Dataloggers UxxxxM and UxxxxG U0141M U0141G models...
Page 61: ...IE LGR UxxxxM 23 61 Dimensions U0110M U0110G U8410M U8410G U0121M U0121G...
Page 62: ...62 IE LGR UxxxxM 23 U0141M U0141G U3120M U3120G U4440M U4440G...
Page 63: ...IE LGR UxxxxM 23 63 U3121M U3121G U3631M U3631G...
Page 64: ...64 IE LGR UxxxxM 23 U0141TM U0141TG U0843M U0843G U5841M U5841G U6841M U6841G U7841M U7841G...