IE-LGR-UxxxxM-23
13
A continuous recording with a preset interval is ON and running.
The recording is ON in the device and it is running at present.
This kind of display is only used, when the recording activity is
dependent on the alarm or the external input condition.
The recording is ON in the device but it is not running at present.
For instance, the rrecording is ON during an alarm only, and there
is no alarm just now. Or, a recording is ON that is controlled by
an external input which not active at the moment.
The LOG symbol is not displayed: The recording is OFF in the device.
The recording is not allowed in any channel in the device’s
configuration.
Meaning of the values displayed
- this item specifies the meaning
of the measured values displayed in the two main rows. Beside the currently
measured values the device will also evaluate the minimum and maximum
values from their last resetting by the user.
If the device is OFF and has not
been running for some time, then, after it is turning ON, the value of Min /
Max is then set to the values before switching OFF.
It can be preset
in the device configuration, whether and in what manner these Min/Max
values will be displayed by the device. Remember that the Min/Max
in question are different from those being recorded.
Neither MIN nor MAX is displayed. You can see values that
have been currently measured.
In both display rows you can see the minimum values measured
since their last resetting by the user.
In both display rows you can see the maximum values measured
since their last resetting by the user.
Alarm condition
- this item provides instant information that at least one
of the alarms which have been preset is active. Alarms can be generated by
exceeding the limits that have been preset in individual channels. Moreover,
they can notify of a device failure. In the device configuration you can preset
which conditions should be considered as alarm generating. By means
of the upper key you can easily browse through the values measured in all
device channels (if enabled in device configuration). In the case
that the value is preceded by a bell-like icon, the preset limits (alarms) have
been exceeded in this channel.
Radio modem active
- this symbol indicates that a power supply has been
connected to the radio modem because of some online work.
Summary of Contents for U0110G
Page 5: ...IE LGR UxxxxM 23 5 Dataloggers UxxxxM and UxxxxG U0141M U0141G models...
Page 61: ...IE LGR UxxxxM 23 61 Dimensions U0110M U0110G U8410M U8410G U0121M U0121G...
Page 62: ...62 IE LGR UxxxxM 23 U0141M U0141G U3120M U3120G U4440M U4440G...
Page 63: ...IE LGR UxxxxM 23 63 U3121M U3121G U3631M U3631G...
Page 64: ...64 IE LGR UxxxxM 23 U0141TM U0141TG U0843M U0843G U5841M U5841G U6841M U6841G U7841M U7841G...