C3G-SIM
SYSTEM INTERLOCK MODULE
System I/O module which interfaces certain control unit internal assemblies; it manages the I/O to the transfer and implements part of
the safety circuits with relay logic.
The outputs to the transfer are protected by fuse with specific indication on the monitoring system in the event of breakage.
It is a VME bus slave module.
FRONT PANEL
MEANING
LED
Colour
Description
A1
A2
A3
A4
A5
A6
A7
A8
B1
B2
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
Remote DRIVE ON (INP 9)
Remote DRIVE OFF (INP 10)
Remote START (INP 11)
Remote HOLD (INP 12)
Remote U1 (INP 13)
Remote U2 (INP 14)
Remote U3 (INP 15)
Remote U4 (INP 16)
Spare external input (INP 8)
External safety / External emerg. stop (INP4)
B3
B4
B5
B6
B7
B8
C1
C2
C3
C4
C5
C6
C7
C8
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
Machine 1 alarm (INP 17)
Machine 1 flange (INP 18)
Air pressure (INP 19)
Not used (INP 25)
Not used (INP 26)
Auto/Local (INP 27)
DRIVE ON/OFF to remote (OUT 9)
START/HOLD to remote (OUT 10)
U1 to remote (OUT 13)
U2 to remote (OUT 14)
U3 to remote (OUT 15)
U4 to remote (OUT 16)
Remote/Local to remote (OUT 11)
Enable/Disable teach to remote (OUT 12)
D1
D2
D3
D4
D5
D6
D7
D8
FUSE
RED
ROSSO
RED
RED
RED
RED
RED
RED
RED
Alarm to remote (OUT 4)
DRIVE ON command (OUT 1)
DRIVE ON enable (OUT 2)
Spare external output (OUT 3)
Alarms inhibit (OUT 5)
Alarm (OUT 7)
System ON (OUT 8)
Low voltge during prog. (OUT 6)
Monitor fuse 1 (INP FUSE)
SIM Module connectors
Connector
Pin no.
Functions
J3
female 15
CONNECTOR WITH OPERATOR PANEL
Carries the following signals:
- EMERGENCY STOP (double channel)
- Programming terminal/EMC connected
- 24 Vdc supply to Operator Panel
J4
male 25
AC POWER DISTRIBUTION CONNECTOR
Carries the following signals:
- Commands to contactors and contactor status feed-back
- External EMERGENCY STOP
- Safety gate external emergency
- 24 Vdc fuse monitoring, machines and transfer
- Monitoring of correct operation of the power on and off
chain relays
- 24 Vdc supply for logic to SIM module relays
J5
male 50
EXTERNAL CONNECTION BOX CONNECTOR
Carries the following signals:
- Input from transfer
- Output to transfer
- Input and alarms from machine
- Servo Control CPU OK and Robot CPU OK
leading from the safety relays of the two modules
P1
96
VME BUS CONNECTOR
REPLACEMENTS
Specific cautions:
·
Comply with the “GENERAL RULES FOR MAINTENANCE” given in this chapter.
Special tools:
unnecessary
C3G
Plus
MAINTENANCE
07/1200
7-47
LAYOUT
CONTROL
UNIT
C3G-SIM
Summary of Contents for C3G Plus
Page 6: ...This page has been intentionally blank UPDATING LIST C3G Plus D 08 0702 ...
Page 14: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 24: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 26: ...This page has been left intentionally blank INSTALLATION C3G Plus 2 ii 01 0498 SUMMARY ...
Page 48: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 122: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 127: ...C3G Plus INTEGRATION GUIDE 06 0400 4 5 SYSTEM I O ...
Page 160: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 182: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 188: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 190: ...This page has been left intentionally blank MAINTENANCE C3G Plus 7 ii 00 1097 GENERAL RULES ...
Page 225: ...X30 connector test device C3G Plus MAINTENANCE 01 0498 7 35 diagnostic ...
Page 264: ...This page has been intentionally blank 7 74 08 0702 MAINTENANCE C3G Plus LIST OF SPARE PARTS ...
Page 265: ...OPERATOR S NOTES C3G Plus NOTES ...
Page 266: ...C3G Plus NOTES ...