START PROCEDURE
The START procedure from remote permits activation of the robot cycle after making all the system checks
and checking the DRIVE ON status. This procedure is active only if the status selector on the operator panel
is in the Automatic Remote position
. The control unit does not switch to Start status if the DRIVE ON
command has not been removed.
1.
On the remote panel:
- if there is an alarm signal (ALARM at low logic level pin 29 on X30) the DRIVE OFF signal is sent pre-
venting activation of the cycle;
- if the robot is in DRIVE ON status (pin 8 on X30), and the power contactor is not closed, an alarm is
generated;
- if the robot is in DRIVE ON status and the power contactor is closed;
the DRIVE ON command is deactivated (pin 1 on X30) and the START command is activated (pin 2 on
X30).
2.
On the controller, if the following conditions are found:
- DRIVE ON (pin 1 on X30) not active (false);
- DRIVE OFF (pin 19 on X30) active (true);
- START (pin 2 on X30) active (true);
- HOLD (pin 20 on X30) active (true);
the START signal (pin 26 on X30) is activated which causes activation of the “holdable” programmes in-
stalled. For the programme installation procedures refer to the Programming manuals.
HOLD PROCEDURE
This procedure is activated if the machine is in the START status (active cycle).
1.
On the remote panel:
- it activates the HOLD command (low logic level pin 20 on X30);
- a timer is initialised.
2.
On the controller:
- the cycle is interrupted;
- the START/HOLD output is deactivated (low logic level pin 26 on X30).
3.
On the remote panel, if the following conditions are found:
- START/HOLD output not active (false);
- ALARM output active (true);
- DRIVE ON/OFF output active (true);
the timer initialised in step 1 is reset.
HOLD PROCEDURE FROM LOCAL
The stop commands (DRIVE OFF and HOLD) are always active regardless of the position of the PRO-
GRAMMING,
, Automatic LOCAL,
, Automatic REMOTE
. status selector. It is therefore possi-
ble that a HOLD command be activated from the PTU4 while the control unit is in Remote status and,
consequently all “holdable” programmes being run are stopped.
C3G
Plus
INTEGRATION GUIDE
00/1097
4-9
COMMAnds
procedure
Summary of Contents for C3G Plus
Page 6: ...This page has been intentionally blank UPDATING LIST C3G Plus D 08 0702 ...
Page 14: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 24: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 26: ...This page has been left intentionally blank INSTALLATION C3G Plus 2 ii 01 0498 SUMMARY ...
Page 48: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 122: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 127: ...C3G Plus INTEGRATION GUIDE 06 0400 4 5 SYSTEM I O ...
Page 160: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 182: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 188: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 190: ...This page has been left intentionally blank MAINTENANCE C3G Plus 7 ii 00 1097 GENERAL RULES ...
Page 225: ...X30 connector test device C3G Plus MAINTENANCE 01 0498 7 35 diagnostic ...
Page 264: ...This page has been intentionally blank 7 74 08 0702 MAINTENANCE C3G Plus LIST OF SPARE PARTS ...
Page 265: ...OPERATOR S NOTES C3G Plus NOTES ...
Page 266: ...C3G Plus NOTES ...