C3G-DLO
32 DC 0,5 A OUTPUT MODULE
VME output module compatible with slave type interface capable of supporting 32 dc Outputs (0.5 A) with signalling through activation
of LEDs on the front panel when the outputs are active.
It may be added on the Control Unit rack starting from the first free slot at the right of the basic configuration modules.
The outputs are protected by fuse with specific indication on the monitoring system if it is tripped.
TECHNICAL CHARACTERISTICS
OUTPUT
Number of outputs
32
Number of common returns
4
Fuses (one for each common return)
5 A 125 V “Normal Blow” 5 x 20
Type of output
Transistor
Operating voltage
4.5 to 36.0 Vdc
Maximum output current with channel not activated
0.2 mA
Maximum voltage drop with channel active
1.8 Vdc
Maximum output current with all channels active
0.5 A @ ta = 25°C
0.4 A @ ta = 45°C
Protection against transients
Through diode
SIGNAL ALLOCATION
SIGNAL
RED
LED
CONN. J3 PIN
(MOD. FRONT)
CONN. X3X PIN
(CABINET BASE)
SIGNAL
RED
LED
CONN. J3 PIN
(MOD. FRONT)
CONN. X3X PIN
(CABINET BASE)
OUTPUT 1
A1
A1
A1
OUTPUT 17
C1
C1
C1
OUTPUT 2
A2
A2
A2
OUTPUT 18
C2
C2
C2
OUTPUT 3
A3
A3
A3
OUTPUT 19
C3
C3
C3
OUTPUT 4
A4
A4
A4
OUTPUT 20
C4
C4
C4
OUTPUT 5
A5
A5
A5
OUTPUT 21
C5
C5
C5
OUTPUT 6
A6
A6
A6
OUTPUT 22
C6
C6
C6
OUTPUT 7
A7
A7
A7
OUTPUT 23
C7
C7
C7
OUTPUT 8
A8
A8
A8
OUTPUT 24
C8
C8
C8
OUTPUT 9
B1
B1
B1
OUTPUT 25
D1
D1
D1
OUTPUT 10
B2
B2
B2
OUTPUT 26
D2
D2
D2
OUTPUT 11
B3
B3
B3
OUTPUT 27
D3
D3
D3
OUTPUT 12
B4
B4
B4
OUTPUT 28
D4
D4
D4
OUTPUT 13
B5
B5
B5
OUTPUT 29
D5
D5
D5
OUTPUT 14
B6
B6
B6
OUTPUT 30
D6
D6
D6
OUTPUT 15
B7
B7
B7
OUTPUT 31
D7
D7
D7
OUTPUT 16
B8
B8
B8
OUTPUT 32
D8
D8
D8
OUT 1
¸
8 COM.
–
AC
A10
OUT. 17
¸
24 COM.
–
CC
C10
OUT 1
¸
8 RET.
–
AR
A12
OUT. 17
¸
24 RET.
–
CR
C12
OUT 9
¸
16 COM.
–
BC
B10
OUT. 25
¸
32 COM.
–
DC
D10
OUT 9
¸
16 RET.
–
BR
B12
OUT. 25
¸
32 RET.
–
DR
D12
OUT. COM.
EARTH FUSE
FUSE
–
–
C3G
Plus
INTEGRATION GUIDE
01/0498
4-27
parallel
i/o
C3G-DLO
EXAMPLE OF CONNECTION
Summary of Contents for C3G Plus
Page 6: ...This page has been intentionally blank UPDATING LIST C3G Plus D 08 0702 ...
Page 14: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 24: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 26: ...This page has been left intentionally blank INSTALLATION C3G Plus 2 ii 01 0498 SUMMARY ...
Page 48: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 122: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 127: ...C3G Plus INTEGRATION GUIDE 06 0400 4 5 SYSTEM I O ...
Page 160: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 182: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 188: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Page 190: ...This page has been left intentionally blank MAINTENANCE C3G Plus 7 ii 00 1097 GENERAL RULES ...
Page 225: ...X30 connector test device C3G Plus MAINTENANCE 01 0498 7 35 diagnostic ...
Page 264: ...This page has been intentionally blank 7 74 08 0702 MAINTENANCE C3G Plus LIST OF SPARE PARTS ...
Page 265: ...OPERATOR S NOTES C3G Plus NOTES ...
Page 266: ...C3G Plus NOTES ...