11
English
ProSpot 150 LX
may operate in one of 4 different modes, which may require varied cable arrangements:
8.1. Automated operation “solo”
8.2. Operation via DMX 512
8.3. Synchronising multiple ProSpot 150 LX fixtures without DMX
8.4. Synchronising multiple ProSpot 150 LX fixtures via 6 channels of DMX
Depending upon which mode you wish to operate in, you should consult the appropriate instructions below:
8.1. Automated operation “solo”
ProSpot 150 LX
may operate independently, executing pre-recorded programs which cause it to change colours, gobos, and posi-
tions (see “Recording programs to the internal memory”) activated via the +/-/menu/enter, without the need for an external control
signal.
In this mode of operation, there is no connection to the unit via the XLR 3 sockets labeled DMX 512 in and out.
8.2. Operation via DMX 512
Control signal is digital, and is transmitted via two pair screened ø0.5mm cable.
Connection is serial, utilising the XLR 3 male and female sockets located on the base of the
ProSpot 150 LX
, labeled DMX 512.
If using a controller which output signal via an XLR 5 (5 pin) socket, do not use pins 4 and 5, leaving them unconnected.
Pin connections conform to the international standard:
pin 1= screening 0 volt
pin 4= not connected
pin 2= data -
pin 5= not connected
pin 3= data +
Connection using a 3 pin XLR 3
Ensure that all data conductors are isolated from one another and the metal housing of the connector.
Note: the housing of the cannon XLR connectors being used must be isolated.
out
Controller
Standard
DMX 512
OUT
3
2
1
3 pin XLR 3/F
3 pin XLR 3/M
Ad altri
ProSpot 150 LX
Connect to other
ProSpot 150 LX
in
out
in
8. Signal connection