13
English
8.4. Synchronising multiple ProSpot 150 LX fixtures via 6 channels of DMX
Multiple
ProSpot 150 LX
units may run any of the internally recorded programs, with control over step times and fade times, using
6 channels of standard DMX signal. Connection and operation is as per the normal DMX standard. The projectors must be set to
operate in REM mode (see section 14 for software information).
Control signal is digital, and is transmitted via two pair screened ø0.5mm cable.
Connection is serial, up to a maximum of 32 projectors, utilising the mala and female XLR 3 sockets located on the base of the
ProSpot 150 LX
labeled
DMX 512 In
and
OUT
.
If connecting more than 10 units, we recommend the us of a suitable opto-isolated connecting unit to amplify the signal as requi-
red. If using a controller which output signal via an XLR 5 (5 pin) socket, do not use pins 4 and 5, leaving them unconnected.
Pin connections conform to the international standard:
pin 1= screening 0 volt
pin 4= not connected
pin 2= data -
pin 5= not connected
pin 3= data +
Ensure that all data conductors are isolated from one another and the metal housing of the connector.
Note: the housing of the cannon XLR connectors being used must be isolated.
out
Controller
Standard
DMX 512
OUT
3
2
1
3 pin XLR 3/F
3 pin XLR 3/M
Ad altri
ProSpot 150 LX
Connect to other
ProSpot 150 LX
in
out
in