4) Insert the lamp. The lamp used is manufactured from quartz
glass and should be handled with care; always adhere to
the instructions supplied in the lamp’s packaging. The G 12
lampholder is symmetrical in construction. DO NOT USE
UNDUE FORCE. Incase of difficulty, re-read the instructions
and repeat the procedure.
5) Replace the lamp assembly (
B
) into its original position and replace and retighten the two screws (
A
) which were previously removed.
Attention:
we recommend that the lamp be realigned in the optical train of the unit to avoid overheating of the dichroic filters
and other internal components of the unit. refer to section 16 for instructions about this procedure.