Fire prevention:
1.
ProSpot 150 LX
utilises a Philips CDM-SA/T 150W lamp or equivalent; the use of any other lamp is not recommended and will
null and void the fixture’s warranty.
2.
Never locate the fixture on any flammable surface.
3.
Minimum distance from flammable materials: 0,5 m.
4.
Minimum distance from the closest illuminable surface: 2 m.
5.
Replace any blown or damaged fuses only with those of identical values. Refer to the schematic diagram if there is any doubt.
6.
Connect the projector to mains power via a thermal magnetic circuit breaker.
Prevention of electric shock:
1.
High voltage is present in the internals of the unit. Isolate the projector from mains supply prior to performing any function which
involves touching the internals of the unit, including lamp replacement.
2.
For mains connection, adhere strictly to the guidelines outlined in section 7 of this manual.
3.
The level of technology inherent in the
ProSpot 150 LX
requires the use of specialised personnel for all service applications; refer
all work to your authorised
coemar
service centre.
4.
A good earth connection is essential for proper functioning of the projector.
Never operate the unit without proper earth connection.
5.
The fixture should never be located in an exposed position, or in areas of extreme humidity. A steady supply of circulating air is
essential.
Protection against ultraviolet radiation
1.
Never turn on the lamp if any of the lenses, filters, or the housing is damaged; their respective functions will only operate efficiently
if they are in perfect working order.
2.
Never look directly into the lamp when it is operating.
Safety:
1.
The projector should always be installed with bolts, clamps, and other fixings which are suitably rated to support the weight of
the unit.
2.
Always use a secondary safety chain of a suitable rating to sustain the weight of the unit in case of the failure of the primary fixing
point.
3.
The external surface of the unit, at various points, may exceed 80°C. Never handle the unit until at least 10 minutes have elap-
sed since the lamp was turned off.
4.
Never install the fixture where unauthorised and untrained personnel may tamper with it.
5.
Always replace the lamp if any physical damage is evident.
6.
Never install the fixture in an enclosed area lacking sufficient air flow; the ambient temperature should not exceed 35°C.
7.
A hot lamp may explode. always wait for at least 10 minutes to elapse after the unit has been turned off prior to attempting to
replace the lamp.
Always wear suitable hand protection when handling the lamp.
Protection rating of the body against liquids and solids:
1.
The fixture is classified as an ordinary fixture, its protection rating against liquids and solids is IP 20.
3. Important safety information