1 9
RESTORE DEFAULT VALUES
PRESS and HOLD the RESET button for 30 seconds to reset all configuration
settings to the default values. A long red flash on the front-panel LED will
indicate the reset has been successful. After a successful reset, power cycle
the CDT100 MK3.
If there was an issue resetting the CDT100 MK3 to the default values, the
front panel LED will flash 8 quick red flashes. If you see 8 quick red LED
flashes, try to reset the system again by holding the RESET for an additional
30 seconds.
EMERGENCY FIRMWARE RECOVERY
Holding both the TEST and RESET buttons while powering on the CDT100
MK3 will cause the unit to enter emergency firmware recovery mode. When
both buttons are pressed while powering on the unit, the last downloaded
firmware will be loaded into the system.
FRONT PANEL LED INDICATOR
The front-panel Power LED also serves as a status indicator.
GREEN: The CDT100 MK3 is functioning normally.
YELLOW: The CDT100 MK3 is in firmware update mode.
BLINKING YELLOW: A firmware update is in progress.
1 LONG RED FLASH: Configuration settings were successfully reset.
3 LONG RED FLASHES: The +12V input power supply voltage is too high.
This will repeat every 15 seconds until the voltage is restored to the proper
level.
3 SHORT RED BLINKS: The +12V input power supply voltage is too low.
This will repeat every 15 seconds until the voltage is restored to the proper
level.
4 SHORT RED BLINKS: Firmware updated failed.
8 SHORT RED BLINKS: Configuration settings could not be reset to the
default settings.