Models 24-CGA-10, 24CGP-10, 24-CEA-10, 24-CEP-10
SteamCraft 10 Service Manual, Chapter 4
Page 65
WARNING
The liquid phosphoric acid in descaling kit 104394 can
be harmful it not handled properly. Follow these basic
safety rules for handling and using acid.
Wear protective clothing when mixing or applying
chemical cleaners. Wear rubber gloves, mask and
approved cup-type goggles.
Avoid breathing fumes. If liquid comes in contact with
skin, flush immediately with large quantities of cold
water. Remove contaminated clothing.
If chemical contacts eyes, flush with cold water for a
minimum of 15 minutes. Get
immediate
medical
attention.
If chemical is swallowed or ingested, follow in-
structions on the chemical container. Get
imme diate
medical attention.
Cleveland Range, Inc.
Printed 3/93
CAUTION
Do not use powdered sulphoric acid, part number
101751. This material will damage the float assembly
and other SteamCraft 10 components.
Do not scrape heating elements with a solid tool.
Figure 4-1 - Steam Generator Cover Plate
Electric Atmospheric Model 24-CEA-10
If the steamer is turned OFF, energize the steamer by pressing the ON/OFF
switch to ON. Allow time for the steam generator to fill (3 to 4 minutes).
This assures that blowdown occurs.
1. Press the ON/OFF switch to OFF.
2. Press the TIMED/MANUAL
switch to TIMED. Set timer to 0.
3. After completion of blowdown (3 minutes), turn off power at the main
disconnect switch.
4. Allow time for the steam generator and compartment to cool down.
5. Access steam generator descaling port.
• Electric Atmospheric Model (24-CEA-10):
a. Remove right side access panel (see Figure 2-7).
b. Remove the 3x3 inch cover plate. See Figure 4-1.
• Electric Pressure and All Gas Models (24-CEP-10, 24-CGA-10. and 24-
CGP-10):
a. On gas models, loosen mounting screws of exhaust vent and remove
exhaust vent.