Page 20
Chapter 2, SteamCraft 10 Service Manual
Models 24-CGA-10, 24-CGP-10, 24-CEA-10, 24-CEP-10
Figure 2-5. Slide Rack Installation
4. Move the SteamCraft 10 into position.
5. Check the adjusting foot of the leg in the highest corner (marked in step 3). The
foot should be fully retracted and provide a 6-inch clearance under the unit.
6. Using a level, adjust the other three legs until the Steam Craft 10 is level both front
to back and side to side.
7. After the Steam Craft 10 has been positioned and leveled, install the slide racks as
described below.
Install Slide Racks
1. Refer to Figure 2-5. There are two slide racks for each cooking compartment. Each
rack has four loops: two at the top and two at the bottom. Hold the slide rack so
the ends of the hanger loops point down, as shown in the figure.
2. Slide one rack into the compartment with loops toward the compartment wall and
mounting pins.
3. Hook the loops over the top and bottom pins.
4. Repeat steps 1 through 3 for each of the other racks.
Install and Connect the Free Air
Vented Drain Lines
The drain outlet must be free air vented to equalize the pressure in the Steam Craft 10
Steamer with the atmosphere. Generating steam causes pressure to increase in the
unit; cold water flow into the condenser creates a vacuum (low pressure) in the
condenser. Without a free air vent, either high or low pressure in the compartment
will cause malfunction or damage.
• Pressure build up in the steamer will cause steam and hot water leakage around the
door.
• A vacuum will implode the steamer and cause permanent physical damage.
Refer to Figure 2-6, and the dimension drawings (Figure 2-2). The drain outlet (D)
discharges exhaust steam and hot condensate from the steamer. The drain exhaust
vent and a 1-inch minimum clearance between the drain opening and floor drain
provide the SteamCraft 10 Steamer with free air venting.
Furnishing and installing the drain lines and fittings is the responsibility of the owner
and/or installer. Figure 2-6 illustrates a drain layout recommended by Cleveland
Range. Observe the following instructions to determine the pipe size, the number of
fittings required, and the layout of the drain line.