Figure 6-12. Water Fill Solenoid
Valve 24-CGA-10
CT:5 ON/OFF Switch
Cleveland Range, Inc.
Printed 3/93
Models 24-CGA-10, and 24-CEA-10
SteamCraft 10 Service Manual, Chapter 6 Page 127
If the
valve fills the generator to the high level and stops, the valve is
operating properly.
a. Reconnect the gray wire to the 3-minute timer terminal 2.
b. Set the ON/OFF switch to the ON position.
c. Test the float high level switch.
In the following procedure, replace the notation 115/120 VAC with the
correct operating voltage for the SteamCraft 10 model being serviced.
• The correct operating voltage for 24-CEA-10 models is 120
VAC
.
• The correct operating voltage for 24-CGA-10 models is 115
VAC
.
1. Set the voltmeter to the 250 VAC scale.
2. Set the ON/OFF switch to the ON position.
• If the red indicator lights, proceed to step 3.
• If the red indicator does not light, proceed to step 4.
3. Set the ON/OFF switch to the OFF position. Refer to Figures 6-13 and 6-
14, and check for 115/120 VAC across the top terminals of the ON/OFF
switch (white/gray and gray wires on model 24-CGA-10) or (white/blue
and gray wires on model 24-CEA-10).
• If the meter reads 115/120 VAC, the ON/OFF switch is good. End this
procedure here.
• If the meter does not read 115/120 VAC, replace the ON/OFF switch
and end this procedure here.
4. Refer to Figures 6-13, 6-14, and 6-15. Check for 115/120 VAC across
the center terminals of the ON/OFF switch (white and black wires).
• If the meter reads 115/120 VAC, continue this test with step 5.
• If the meter does not read 115/120 VAC, the fault is not in the switch.
5. Refer to Figures 6-13, 6-14, and 6-15. Check for 115/120 VAC across
the bottom terminals of the ON/OFF switch (pink, red and white,
white/red wires on model 24-CEA-10) or (pink, black and white, white
wires or model 24-CGA-10).
• If the meter reads 115/120 VAC, continue this procedure with step 6.
Figure 6-13. ON/OFF Switch - 24-CEA-
10
Figure 6-14. ON/OFF Switch - 24-CGA-
10 Electronic