Models 24-CGA-10, and 24-CEA-10
SteamCraft 10 Service Manual, Chapter 6
Page 97
The third item are the Yes/No arrows in the left column The arrows direct the
test technician from one test or action to the next. In most cases: continue on to
the next left column item for "YES" answers, and follow the instructions to test
or repair the component for "NO" answers.
INITIAL TEST PROCEDURE - GENERAL PREPARATIONS
For both Models 24-CGA-10 and 24-CEA-10, perform the following checks and
inspections before starting the INITIAL TEST PROCEDURE for the specific
model being tested.
1. If not already done, review the COMPONENT TESTING FUNDAMENTALS
section starting on page 96.
2. Ask the person in charge of the SteamCraft 10 about the unit's performance
history, and specifically about the current problems or symptoms. For example:
• How was the unit working before this specific problem started?
• How was the unit being used when it malfunctioned?
• How did the unit operate during the malfunction?
• How long after installation did the trouble Start?
• How long has the unit been malfunctioning?
• How has the unit been used (if at all) since the problem started?
3. Equipment damage and faulty operation will result if the drain, gas, water, or
electrical supplies fall below requirements. This may be caused by other
equipment on the same supply lines.
• Determine the number, type, and supply requirements of all equipment sharing
supply lines with the SteamCraft 10.
• If it seems the SteamCraft 10 problems are caused by overburdened supply
lines, turn off all other equipment sharing the supply lines, and operate the
SteamCraft 10. If the operating problems stop, remove some of the equipment
from the common supply lines.
• If the supply lines are not overburdened, turn on all equipment drawing from
the same utility supply lines during all tests, adjustments, and inspection of the
SteamCraft 10.
4. Proper operation of the SteamCraft 10 is dependent upon proper installation.
Review the INSTALLATION CHECKS on page 34 and make sure the
equipment is installed properly and the installation meets all the warranty
requirements.
Model Numbers and Test Procedure Variations
The control circuits and therefore the tests vary for each model. To address these
variations with clarity, separate procedures are used. After completing the general
preparations, start the procedure which applies to the SteamCraft 10 model being
tested.
The Initial Testing Procedure for the:
Model 24-CGA-10 starts on page 98.
Model 24-CEA-10 starts on page 111.
Cleveland Range, Inc.
Printed 3/93