Models 24-CGA-10, 24-CGP-10, 24-CEA-10, 24-CEP-10
SteamCraft 10 Service Manual, Chapter 2
Page 39
Figure 2-19. Steam Generator
Controls Pressure Units Only
b. The condenser solenoid clicks open and condenser flow starts. A
small stream of water flows from the drain pipe.
c. If the float cylinder water level drops below the initial fill level, the
water fill valve opens and fills the generator. A dull roaring sound
indicates the heater is working and the unit is beginning to generate
steam.
d. As the unit generates steam, the water level fluctuates and a clicking
sound is heard as the solenoid opens and closes the fill valve. The
level in the float cylinder rises and falls about 1/4 inch as the fill
valve operates.
e. When the timer counts down to zero, the heating system turns off, the
condenser flow stops, and the buzzer sounds for 3 seconds.
f. After about 30 seconds, steam stops entering the cooking
compartment.
6. Turn the SteamCraft 10 off by pressing the OFF (bottom) end of the
ON/OFF switch. The red indicator on the switch turns off immediately.
and the automatic blowdown cycle starts. DO NOT turn off the power at
the main disconnect switch until blowdown is complete. The cycle takes
about 3 minutes.
7. When blowdown is complete, turn the steamer off at the main disconnect
switch.
8. Install the right side access panel and secure it in place with three screws
(see Figure 2-7). After completing the Initial Setup and Blowdown
Inspection procedure, and the Operating Test procedure, the SteamCraft
10 is ready for service. Refer to Chapter 3 for complete operating
instructions.