Models 24-CGA-10, 24-CGP-10, 24-CEA-10, 24-CEP-10
SteamCraft 10 Service Manual, Chapter 3
Page 47
Power ON (Automatic Fill)
When the SteamCraft 10 is turned on, it automatically fills the steam
generator with water. Use this procedure at the beginning of a shift to
prepare the steamer for operation without Starting steam generation. When
ready to start steam cooking, begin either the Timed or Manual Operating
Procedure.
1. At the beginning of this procedure the ON/OFF switch is in the OFF
(bottom) position. The control panel circuits are not powered and the
timer display is blank.
2. Press the TIMED (top) end of the TIMED/MANUAL switch.
3. Press the ON (top) end of the ON/OFF switch to energize the SteamCraft
10 control panel. The red indicator on the switch lights, and water fills
the steam generator.
START-UP INSTRUCTIONS FOR GAS-FIRED
STEAM GENERATORS
1. Turn on the main power switch (ON/OFF Switch).
• Generator will fill with water (about 5 minutes).
• Blower will start and pilot will attempt to light for 90
seconds.
• If no ignition occurs, the system will automatically reset
in 6-7 minutes.
2. System may be reset manually by turning the power
switch (ON/OFF Switch) off for 5 minutes and back on.
4. During the fill cycle, check the timer display. If the timer is not zeroed
(00:00), clear the timer by pressing and holding the CLEAR key on the
key pad control panel.
5. When the generator is full, the SteamCraft 10 automatically stops water
flow.
Start Steam Supply
On pressure units, press the Steam switch to heat the water in the
generator. In atmospheric units, the water is automatically heated after
filling when the ON/OFF switch is turned on.
Inspect the Cooking Compartment
CAUTION
Steam leaks around the door, cooking compartment
flooding, reduced cooking performance, and
compartment implosion can be caused by a blocked
drain or drain screen. Inspect and clean the drain and
drain screen before each use. Never operate the steamer
without the screen in place.