As needed
Required/As Needed
Onsite
Onsite/Remote
None
Security Level
Procedure
Step 1
Complete the
DLP-G653 Remove the Fiber Module, on page 122
.
Step 2
Complete the
DLP-G654 Install the Cable Module, on page 123
.
Step 3
Complete the
DLP-G655 Route and Lock Cables, on page 124
.
Stop. You have completed this procedure.
DLP-G653 Remove the Fiber Module
This procedure removes the default fiber module in the ONS 15454 M6 system.
Purpose
#1 Phillips cross-head PH screwdriver
Tools/Equipment
None
Prerequisite Procedures
As needed
Required/As Needed
Onsite
Onsite/Remote
None
Security Level
Procedure
Step 1
Loosen the screws on the fiber module present on the right side of the ONS 15454 M6 assembly. (See the
following figure.)
Step 2
Loosen the screw present on the air filter locking feature of the ONS 15454 M6 shelf.
Step 3
Remove the air filter locking feature by holding the air filter and gently pulling the air filter locking feature
away from the shelf.
Step 4
Extract the fiber module by gently removing it from the ONS 15454 M6 shelf.
Installing the ONS 15454 M6 Shelf
122
Installing the ONS 15454 M6 Shelf
DLP-G653 Remove the Fiber Module