S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
37-11
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 37 Configuring and Managing VSANs
Displaying Static VSAN Configuration
About Interop Mode
Interoperability enables the products of multiple vendors to connect with each other. Fibre Channel
standards guide vendors to create common external Fibre Channel interfaces. For additional information,
see the
“Switch Interoperability” section on page 43-9
.
Displaying Static VSAN Configuration
The following example shows how to display information about a specific VSAN:
switch#
show vsan 100
...
The following example shows how to display VSAN usage:
switch#
show vsan usage
4 vsan configured
configured vsans:1-4
vsans available for configuration:5-4093
The following example shows how to display all VSANs:
switch#
show vsan
Default Settings
Table 37-2
lists the default settings for all configured VSANs.
Table 37-2
Default VSAN Parameters
Parameters
Default
Default VSAN
VSAN 1.
State
Active state.
Name
Concatenation of VSAN and a four-digit string representing the
VSAN ID. For example, VSAN 3 is VSAN0003.
Load-balancing attribute
OX ID (src-dst-ox-id).
Summary of Contents for N5010P-N2K-BE
Page 50: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 102: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 240: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 312: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 400: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 418: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 436: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 658: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...