S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
26-3
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 26 Configuring Smart Call Home
Information About Call Home
destination profile only if that Call Home alert belongs to one of the alert groups associated with that
destination profile and if the alert has a Call Home message severity at or above the message severity set
in the destination profile (see the
“Call Home Message Levels” section on page 26-4
).
Table 26-1
lists supported alert groups and the default CLI command output included in Call Home
messages generated for the alert group.
Table 26-1
Alert Groups and Executed Commands
Alert Group
Description
Executed Commands
Cisco-TAC
All critical alerts from the other alert groups
destined for Smart Call Home.
Execute commands based on the
alert group that originates the alert.
Diagnostic
Events generated by diagnostics.
show diagnostic result module all
detail
show module
show version
show tech-support platform
callhome
Supervisor
hardware
Events related to supervisor modules.
show diagnostic result module all
detail
show module
show version
show tech-support platform
callhome
Linecard hardware
Events related to standard or intelligent
switching modules.
show diagnostic result module all
detail
show module
show version
show tech-support platform
callhome
Configuration
Periodic events related to configuration.
show version
show module
show running-config all
show startup-config
System
Events generated by failure of a software
system that is critical to unit operation.
show system redundancy status
show tech-support
Environmental
Events related to power, fan, and
environment-sensing elements such as
temperature alarms.
show environment
show logging last 1000
show module
show version
show tech-support platform
callhome
Inventory
Inventory status that is provided whenever a
unit is cold booted, or when FRUs are
inserted or removed. This alert is
considered a noncritical event, and the
information is used for status and
entitlement.
show module
show version
show license usage
show inventory
show sprom all
show system uptime
Summary of Contents for N5010P-N2K-BE
Page 50: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 102: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 240: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 312: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 400: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 418: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 436: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 658: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...