S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
34-9
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 34 Configuring N Port Virtualization
Verifying NPV
To display a list of devices on a server interface and their assigned NP uplinks, enter the
show npv
flogi-table
command on the Cisco Nexus 5000 Series switch:
switch#
show npv flogi-table
--------------------------------------------------------------------------------
SERVER
EXTERNAL
INTERFACE VSAN FCID
PORT NAME
NODE NAME
INTERFACE
--------------------------------------------------------------------------------
vfc3/1
1
0xee0008 10:00:00:00:c9:60:e4:9a 20:00:00:00:c9:60:e4:9a fc2/1
vfc3/1
1
0xee0009 20:00:00:00:0a:00:00:01 20:00:00:00:c9:60:e4:9a fc2/2
vfc3/1
1
0xee000a 20:00:00:00:0a:00:00:02 20:00:00:00:c9:60:e4:9a fc2/3
vfc3/1
1
0xee000b 33:33:33:33:33:33:33:33 20:00:00:00:c9:60:e4:9a fc2/4
Total number of flogi = 4
Note
For each server interface, the External Interface value displays the assigned NP uplink.
To display the status of the server interfaces and the NP uplink interfaces, enter the
show npv status
command:
switch#
show npv status
npiv is enabled
External Interfaces:
====================
Interface: fc2/1, VSAN: 1, FCID: 0x1c0000, State: Up
Interface: fc2/2, VSAN: 1, FCID: 0x040000, State: Up
Interface: fc2/3, VSAN: 1, FCID: 0x260000, State: Up
Interface: fc2/4, VSAN: 1, FCID: 0x1a0000, State: Up
Number of External Interfaces: 4
Server Interfaces:
==================
Interface: vfc3/1, VSAN: 1, NPIV: No, State: Up
Number of Server Interfaces: 1
Note
To view fcns database entries for NPV edge switches, you must enter the
show fcns database
command
on the core switch.
To view all the NPV edge switches, enter the
show fcns database
command on the core switch:
core-switch#
show fcns database
For additional details (such as IP addresses, switch names, interface names) about the NPV edge
switches that you see in the
show fcns database
output, enter the
show fcns database detail
command
on the core switch:
core-switch#
show fcns database detail
Verifying NPV Traffic Management
To display the NPV traffic map, enter the
show npv traffic-map
command.
NPV Traffic Map Information:
Summary of Contents for N5010P-N2K-BE
Page 50: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 102: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 240: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 312: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 400: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 418: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 436: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...
Page 658: ...Se n d f e e d b a ck t o n x 5 0 0 0 d o c f e e d b a ck c i s c o c o m ...