9-21
Cisco Unified Communications Manager Managed Services Guide
OL-22523-01
Chapter 9 Vendor-Specific Management Information Base
Hewlett Packard MIBs
•
Rebuilding (7) Indicates that the
logical drive is currently doing
Automatic Data Recovery. During
Automatic Data Recovery, fault
tolerance algorithms restore data to
the replacement drive.
•
Wrong Drive (8) Indicates that the
wrong physical drive was replaced
after a physical drive failure.
•
Bad Connect (9) Indicates that a
physical drive is not responding.
Physical Drive
1
CPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1.1.6
cpqDaPhyDrvStatus
Clearing Value = 2
•
The following values are valid for
the physical drive status:
•
other (1) Indicates that the
instrument agent does not
recognize the drive. You may need
to upgrade your instrument agent
and/or driver software.
•
ok (2) Indicates the drive is
functioning properly.
•
failed (3) Indicates that the drive is
no longer operating and should be
replaced.
•
predictiveFailure(4) Indicates that
the drive has a predictive failure
error and should be replaced.
System Fan
CPQHLTH-MIB
1.3.6.1.4.1.232.6.2.6.4
cpqHeThermalSystem
FanStatus
Clearing Value = 2
This value will be one of the following:
•
other(1) Fan status detection is not
supported by this system or driver.
•
ok(2) The fan is operating properly.
•
degraded(2) A redundant fan is not
operating properly.
•
failed(4) A non-redundant fan is
not operating properly.
Table 9-13
HP Hardware Status Messages, MIBs and OIDs, MIB Object Names and Clearing Values, and
Object Responses (continued)
Cisco Unified CM Release 6.x
MCS-78xx Status
MIB and OID
MIB Object Name and
Clearing Value
Object Response