6-70
Cisco Unified Communications Manager Managed Services Guide
OL-22523-01
Chapter 6 Cisco Unified Serviceability Alarms and CiscoLog Messages
Alert-Level Alarms
ParityConfigurationError
The CMI service parameter, Parity, has an invalid configuration.
An invalid parity has been configured for the serial port that CMI uses to connect to the voice messaging
system. It is possible that the parity value has been updated via AXL or a CLI command where validation
of the value was not performed. For this reason, it is best to set this value in the Service Parameter
Configuration window in Cisco Unified CM Administration and the value can be validated against the
accepted range of values for this field.
Cisco Unified Serviceability Alarm Definition Catalog
CMIAlarmCatalog/CMI
Severity
ALERT
Routing List
Event Log
SDI
Parameter(s)
Illegal Parity(String)
Recommended Action
Verify that the Cisco Messaging Interface service parameter Parity is set to a valid (allowable) value.
SerialPortOpeningError
When CMI tries to open the serial port, the operating system returns an error.
For a system running CMI, the serial port through which the voice messaging system is connected is
always USB0, and that value is configured in the Cisco Messaging Interface service parameter, Serial
Port. It is possible that the Serial Port value has been updated via AXL or a CLI command where
validation of the value was not performed. CMI triggers this alarm if the value in the Serial Port service
parameter is anything other than USB0.
History
Cisco Unified Communications
Release
Action
8.0(1)
New name changed from kParityConfigurationError.
History
Cisco Unified Communications
Release
Action
8.0(1)
New name changed from kSerialPortOpeningError.