7-69
Cisco Unified Communications Manager Managed Services Guide
OL-22523-01
Chapter 7 Cisco Management Information Base
CISCO-CCM-MIB
The time duration for storing each entry in the ccmPhoneStatusUpdateTable. The entries that have
been kept at least this period will be deleted. This value should ideally be set to a higher value than
the ccmPhoneStatusUpdateAlarmInterv object.
DEFVAL { 1800 }
::= { ccmAlarmConfigInfo 5 }
Gateway Alarm Enable
ccmGatewayAlarmEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
Allows the generation of alarms in response to Gateway general failures that the Cisco Unified CM
is aware of.
true(1): Enabling this object will allow the Cisco Unified CM agent to generate the following
alarms:
ccmGatewayFailedReason
ccmGatewayLayer2Change (This is the default value.)
false(2): Disabling this object will stop the generation of the following alarms by the Cisco Unified
agent:
ccmGatewayFailed
ccmGatewayLayer2Change.
DEFVAL { true }
::= { ccmAlarmConfigInfo 6 }
Malicious Call Alarm Enable
ccmMaliciousCallAlarmEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
Allows the generation of alarms for malicious calls that the local call manager is aware of.
true(1): Enabling this object will allow the Cisco Unified CM agent to generate the
ccmMaliciousCall alarm. This is the default value.
false(2): Disabling this object will stop the generation of the ccmMaliciousCall alarm.
DEFVAL { true }
::= { ccmAlarmConfigInfo 7 }