1-31
Catalyst 6500 Series Switches Installation Guide
OL-5781-08
Chapter 1 Product Overview
Catalyst 6509 Switch
Table 1-11
lists the features of the Catalyst 6509 switch chassis.
Table 1-11
Catalyst 6509 Switch Features
Feature
Description
Chassis
•
Nine horizontal slots. Slots are numbered from 1 (top) to 9 (bottom).
Supervisor engines
•
Supports Supervisor Engine 2, Supervisor Engine 32, Supervisor
Engine 32 PISA, Supervisor Engine 720, and Supervisor
Engine 720-10GE.
Note
Refer to your software release notes for the minimum software
release versions required to support the supervisor engines.
–
Supervisor Engine 2 must be installed in slot 1 and slot 2.
–
Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor
Engine 720, and Supervisor Engine 720-10GE must be installed in
slot 5 and slot 6.
Note
Slots not occupied by supervisor engines can be used for modules.
Check your software release notes for any restrictions on the type of
module that can be installed.
•
Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor
Engine 720, and Supervisor Engine 720-10GE require that the
high-speed fan tray be installed in the chassis. You must also install a
2500 W or higher capacity power supply in the chassis to power the
high-speed fan tray.
Note
The 2500 W power supply, when supporting the high-speed fan tray,
can be powered from either 120 VAC or 220 VAC.
•
Supervisor Engine 720 and Supervisor Engine 720-10GE have a built-in
switching fabric. Switch Fabric Modules (WS-C6500-SFM and
WS-X6500-SFM2) are not supported by Supervisor Engine 720 and
Supervisor Engine 720-10GE.
•
Supervisor Engine 32 and Supervisor Engine 32 PISA do not support
the Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2).
•
The uplink ports are fully functional on all redundant supervisor engine
models when they are in standby mode.
Note
In systems with redundant supervisor engines, both supervisor
engines must be the same model and have the same daughter card
configurations. Each supervisor engine must have the resources to
run the switch on its own, which means that all supervisor engine
resources are duplicated. Identical supervisor engine memory
configurations are recommended, but are not required as long as the
supervisor engine with the smaller memory configuration is
sufficient to run the configured features of the switch. Additionally,
each supervisor engine must have its own flash device and console
port connections.