![Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion Installation Manual Download Page 66](http://html.mh-extra.com/html/cisco/6500-catalyst-series-10-gigabit-en-interface-module-expansion/6500-catalyst-series-10-gigabit-en-interface-module-expansion_installation-manual_63867066.webp)
1-46
Catalyst 6500 Series Switches Installation Guide
OL-5781-08
Chapter 1 Product Overview
Catalyst 6509-NEB Switch
Power supply
•
Supports one or two power supplies. The following models are
supported:
–
WS-CAC-2500W (2500 W AC-input power supply).
–
WS-CDC-2500W (2500 W DC-input power supply).
–
WS-CAC-3000W (3000 W AC-input power supply).
–
WS-CAC-4000W-US (4000 W AC-input power supply).
–
WS-CAC-4000W-INT (4000 W AC-input power supply).
–
PWR-4000-DC (4000 W DC-input power supply).
–
WS-CAC-6000W (6000 W AC-input power supply).
–
PWR-6000-DC (6000 W DC-input power supply).
–
WS-CAC-8700W-E (8700 W AC-input power supply).
Note
The 6000 W AC-input and DC-input power supplies and the 8700 W
AC-input power supply are limited to 4000 W maximum output
when installed in the Catalyst 6509-NEB chassis.
•
Installed power supplies can be of different wattage ratings. Installed
power supplies can also be both AC-input, both DC-input, or one
AC-input and one DC-input. Power supplies can be configured in either
redundant or combined mode.
•
All Catalyst 6500 series AC-input power supplies require single-phase
source AC. Source AC can be out of phase between multiple power
supplies or multiple AC-power plugs on the same power supply because
all AC power supply inputs are isolated.
•
Single power supplies are installed in the left power supply bay. The
second power supply is installed in the right power supply bay.
Note
For proper operation of the power supply OUTPUT FAIL LED,
systems with single power supplies must be configured with a
minimum of one fan tray and one supervisor engine. Systems with
dual power supplies must have a minimum configuration of one fan
tray, one supervisor engine, and one additional module. Failure to
meet these minimum configuration requirements can cause a false
power supply output fail signal.
1.
Refer to the
Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note
for kit installation instructions.
Table 1-15
Catalyst 6509-NEB Switch Features (continued)
Feature
Features